<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Research and Health</title>
<title_fa>مجله تخصصی پژوهش و سلامت</title_fa>
<short_title>J Research Health</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrh.gmu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2423-5717</journal_id_issn>
<journal_id_issn_online>2423-5717</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.29252/jrh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی ریسک مواجهه با اشعه X در محیط گیت های امنیت پرواز فرودگاه امام خمینی(ره) تهران</title_fa>
	<title>Level of exposure to X-Ray in security gates of Tehran’s Imam Khomeini airport</title>
	<subject_fa></subject_fa>
	<subject>● Psychosocial Health</subject>
	<content_type_fa>مقاله اصيل پژوهشي</content_type_fa>
	<content_type>Orginal Article</content_type>
	<abstract_fa>&lt;p&gt;&lt;b&gt;مقدمه:&lt;/b&gt; اشعه X از جمله پرتوهای یونیزان امواج الکترومغناطیس می&#8204;باشد که دارای طیف وسیعی است. این امواج علیرغم کاربردهای وسیع و مختلف در پزشکی، صنایع، تحقیقات و&amp;hellip;، اثرات نامطلوب و جبران ناپذیری نیز دارد. یکی از مراکزی که این امواج کاربرد زیادی دارد، بخش&#8204;های کنترلی فرودگاه&#8204;ها است. این مطالعه با هدف بررسی میزان مواجهه لحظه&#8204;ای اپراتورها و پرسنل شاغل با اشعه Xدر گیت&#8204;های بازرسی فرودگاه امام خمینی (ره)انجام شده است.&lt;br&gt;
&lt;b&gt;مواد و روش کار&lt;/b&gt;: دستگاه&#8204; X-Ray موجود در گیت&#8204;های بازرسی فرودگاه امام خمینی(ره) HEIMANN می&#8204;باشد. اندازه&#8204;گیری میزان پرتو در دو قسمت بازرسی آقایان و خانم&#8204;ها در وضعیت&#8204;های پرده پایین، پرده بالا در حین خروج وسایل و اطراف دستگاه و محل نشستن اپراتور در فاصله نیم متری و یک متری انجام شد. اندازه&#8204;گیری تشعشعات X به وسیله دستگاه Smartlon صورت گرفت. نتایج حاصل از اندازه&#8204;گیری با استفاده از آزمون&#8204;های آماری t مورد آنالیز قرار گرفت و میزان اشعه x با حد مجاز استاندارد شغلی انجمن دولتی متخصصین بهداشت صنعتی آمریکا(ACGIH-2012) که &amp;mu;svh-1 25 می&#8204;باشد، مورد مقایسه قرار گرفت.&lt;br&gt;
&lt;b&gt;یافته ها&lt;/b&gt;: میانگین کل میزان اشعه x اندازه&#8204;گیری&#8204;شده در موقعیت های مختلف دستگاه HEIMANN برابر با (&amp;mu;svh-19032/0&amp;plusmn; 02/1) بود. میانگین میزان اشعه ایکس در وضعیت های مختلف پرده بالا، پرده پایین،اطراف دستگاه و محل مانیتورینگ به ترتیب (&amp;mu;svh-145/1&amp;plusmn;8/3) ، (&amp;mu;svh-17/1&amp;plusmn;67/2) ، (&amp;mu;svh-1175/0&amp;plusmn;13/1) و (&amp;mu;svh-158/0&amp;plusmn;47/0)بدست آمد. میزان اشعه اندازه&#8204;گیری شده در قسمت آقایان(&amp;mu;svh-1 985/0&amp;plusmn;3025/1) و در قسمت خانم&#8204;ها(&amp;mu;svh-1658/0&amp;plusmn; 06/1) اندازه گیری شد.میزان اشعه X اندازه گیری شده با استفاده از آزمون آماری t با حد مجاز استاندارد شغلی مقایسه شد که نشان&#8204;دهنده وجود تفاوت معنی&#8204;دار بین میزان اشعه اندازه&#8204;گیری شده با میزان استاندارد می&#8204;باشد. (P&lt;0.05)&lt;br&gt;
&lt;b&gt;بحث و نتیجه گیری: &lt;/b&gt;هرچند که میزان اشعه X در تمامی حالات فوق پایین&#8204;تر از حد مجاز شغلی می&#8204;باشد، ولی در هر حال تماس با این اشعه حتی در دوزهای پایین می&#8204;تواند عوارضی را برای انسان به همراه داشته باشد، بنابرایندر راستای حفظ و ارتقاء سلامتی پرسنل حفاظت پرواز، مانیتورینگ مداوم، تدوین دستورالعمل هایمناسب و دادن آگاهی لازم و کافی در مورد خطرات اشعه و نحوه استفاده ایمن از آن، ضروری و اجتناب ناپذیر است.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;X-Ray is an ionizing electromagnetic radiation with a wide spectrum. A setting where this radiation is widely used is airport security units. This study was conducted to measure the level of momentary exposure to X-Ray in operators and personnel working in security gates of Imam Khomeini airport. In this cross-sectional study, the X-Ray machines used in security gates of Imam Khomeini airport are HEIMANN. The radiation was measured in both men&amp;rsquo;s and women&amp;rsquo;s inspection units, with curtain down and curtain up when passengers&amp;rsquo; luggage coming out of the machine, around the machine, operators&amp;rsquo; seat located half a meter and one meter from the machine. The X-Ray was measured using smartlon. The results were analyzed using t-test, and level of X-Ray was compared to occupational standard limit of American conference of governmental industrial hygienists, 25 &amp;mu;svh-1. Total mean of X-Ray measured in different positions of HEIMANN machine was 1.02 &amp;mu;svh-1 &amp;plusmn; 0.9032 &amp;mu;svh-1. The X-Ray measured in men&amp;rsquo;s and women&amp;rsquo;s inspection units was 1.3025 &amp;mu;svh-1 &amp;plusmn; 0.985 &amp;mu;svh-1 and 1.06 &amp;mu;svh-1 &amp;plusmn; 0.658 &amp;mu;svh-1, respectively. The X-Ray measured in this study was compared to the occupational standard limit using t-test, which indicated a significant difference. Although level of X-Ray in all above cases was lower than the occupational standard limit, any contact with this ray even at low doses may cause complications in humans. Therefore, constant monitoring is essential for maintaining and improving health of airport security staff.&lt;/div&gt;

&lt;div align=&quot;left&quot;&gt;&lt;/div&gt;
</abstract>
	<keyword_fa>Airport, Exposure, Gate, X-Ray</keyword_fa>
	<keyword>Airport, Exposure, Gate, X-Ray</keyword>
	<start_page>563</start_page>
	<end_page>571</end_page>
	<web_url>http://jrh.gmu.ac.ir/browse.php?a_code=A-10-847-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Firouz</first_name>
	<middle_name></middle_name>
	<last_name>Valipour</last_name>
	<suffix></suffix>
	<first_name_fa>فیروز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ولی پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>firouzvalipour@gmail.com</email>
	<code>100319475328460012688</code>
	<orcid>100319475328460012688</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department   of   Occupational   Health,    School  of  Health,  Baqiyatallah  University   of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>Baqiyatallah  University   of Medical Sciences, Tehran</affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Kardan Yamchi</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاردان یامچی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hkardan111@yahoo.com</email>
	<code>100319475328460012689</code>
	<orcid>100319475328460012689</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>  Health  Research   Center,  Baqiyatallah  University  of  Medical   Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>Baqiyatallah  University  of  Medical   Sciences, Tehran,</affiliation_fa>
	 </author>


	<author>
	<first_name>Gholamhossein</first_name>
	<middle_name></middle_name>
	<last_name>Pourtaghi</last_name>
	<suffix></suffix>
	<first_name_fa>غلامحسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پورتقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ghpourtaghi@yahoo.com</email>
	<code>100319475328460012690</code>
	<orcid>100319475328460012690</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department   of   Occupational   Health,    School  of  Health,  Baqiyatallah  University   of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>Baqiyatallah  University   of Medical Sciences, Tehran,</affiliation_fa>
	 </author>


	<author>
	<first_name>Habibollah </first_name>
	<middle_name></middle_name>
	<last_name>Dehghan</last_name>
	<suffix></suffix>
	<first_name_fa>حبیب اله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دهقان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460012691</code>
	<orcid>100319475328460012691</orcid>
	<coreauthor>No</coreauthor>
	<affiliation> Department   of   Occupational   Health    Engineering, Isfahan University of Medical  Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>Isfahan University of Medical  Sciences, Isfahan</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Salem </last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سالم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mohamadsal2000@gmail.com</email>
	<code>100319475328460012692</code>
	<orcid>100319475328460012692</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department   of   Occupational   Health,    School  of  Health,  Baqiyatallah  University   of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>Baqiyatallah  University   of Medical Sciences, Tehran,</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
